No products
View larger
New product
This guideline describes a method for acceptance testing of the specification of a contour-measuring system, as given by its manufacturer; the method relies on the tactile stylus method with two axes for measuring distances, radii, straightness and angles. This guideline also specifies a reverification test allowing the user to verify the conformance with the specification of the contour-measuring system at regular intervals. The acceptance and reverification tests described in this guideline are exclusively for use of tactile styli. This guideline specifies: performance specifications to be met by the contour- measuring system, imposed by either its manufacturer or its user, the performance of the acceptance and reverification tests, rules for proving conformance
| Author | VDI |
|---|---|
| Editor | VDI |
| Document type | Standard |
| Format | File |
| ICS | 17.040.30 : Measuring instruments
|
| Number of pages | 16 |
| Replace | VDI/VDE 2629 Blatt 1 (2005-11) |
| Set | VDI/VDE-Handbuch Fertigungsmesstechnik,VDI-Handbuch Produktionstechnik und Fertigungsverfahren Band 3 |
| Year | 2008 |
| Document history | VDI/VDE 2629 Blatt 1 (2008-08) |
| Country | Germany |
| Keyword | VDI 2629;VDI 2629 Blatt 1;VDI/VDE 2629;2629 |